The biportal approach creates new opportunities in minimally invasive spine surgery by utilizing separate portals for endoscopy and instrumentation. This allows surgeons to benefit from excellent visualization and enhanced freedom of movement throughout the procedure. By combining advanced endoscopy, plasma, and shaver technologies, REGER enables optimal visualization, controlled workflows, and maximum surgical precision throughout the procedure.
Biportal Endoscopes
REGER endoscopes for the biportal approach provide outstanding visualization of the surgical field and enable precise orientation throughout the procedure. Combined with the separate handling of the endoscope and surgical instruments, they offer enhanced flexibility and freedom of movement for the surgeon. High-quality optics, reliable imaging, and a well-designed system architecture support efficient workflows and maximum precision in biportal spine surgery.
| Item No. | Length (mm) | OD (mm) | DoV |
|---|---|---|---|
| 900-4 | 175 | 4,0 | 0° |
| 900-5 | 175 | 4,0 | 30° |
Interlaminar Instruments
Lorem ipsum dolor sit amet, consectetur adipiscing elit. Vivamus vel magna vel magna efficitur efficitur. Sed vel magna vel magna efficitur efficitur.
| Item No. | Item | Description |
|---|---|---|
| SET970-003 | Interlaminar SET | Complete instrument set for interlaminar Spine Endoscopy (PLED/Stenosis) for Scope 900-6 |
| SET970-004 | Interlaminar SET | Complete instrument set for interlaminar Spine Endoscopy (PLED/Stenosis) for Scope 900-15 |
| SET970-005 | Interlaminar SET | Complete instrument set for interlaminar Spine Endoscopy (PLED) for Scope 900-1 |
Biportal RF-Plasma-System
Handles:
- Reusable 250 times (autoclave)
- With or without buttons
- Footswitch compatible
- Ergonomic handpiece design
EndoVap:
- Powerful electrodes
- for Coagulation and Cutting
- Single Use - Electrode
- 5 different Types
- fits into the EndoScope
RF-Plasma Generator:
- Scope Protection
- 350 kHz Fundamental Frequency
- Max. 350 W Output
- Touch-Display
- Instrument Detection
Adapter:
- Reusable adapter
- Simple plug-and-play
- Compatible with most common third-party generator platforms
EndoVap Flex:
- 45° articulating tip
- Reusable cable System for reduced operating costs and waste
- Bipolar forceps connector comptible with various RF generators
RF Generator & Electrodes – Perfectly Matched for Precise Energy Application
The all-in-one system from REGER Medizintechnik combines high-performance HF technology with optimally matched electrodes for endoscopic and open procedures. The generator and instruments work together as a precise unit—ensuring maximum safety, controlled energy delivery, and efficient workflows in the operating room.
- Optimally matched electrodes for precise cutting, coagulation, and ablation
- Smart Instrument Recognition for Quick Deployment
- Maximum safety through scope protection and neutral electrode monitoring
- 350 W power & touchscreen display for convenient control during use
| Item No. | Item | Description |
|---|---|---|
| 897-10 | RF-Plasma Generator | Mains voltage: 230V |
| 897-10V | RF-Plasma Generator | Mains voltage: 110V |
| 897-7 | Foot switch | Foot switch for 897-10(V) |
StenoVap
Plasma Electrode – Perfect for Cutting and Coagulating Tissue
- designed for UBE
- Various tip´s
- Reusable Handle System for reduced operating costs and waste
- with various RF generators compatible
- Powerful and effective workflow
- works with frequencies between 100kHz- 4mHz
| Item No. | Item | Length (mm) | OD (mm) | VPE | Working Frequency | Image |
|---|---|---|---|---|---|---|
| 891-11s | 90° Electrode with Suction | 150 | 4,6 | sterile, Single Use 10 pcs. |
<1 mHz | ![]() |
| 891-12s | 70° Electrode | 150 | 4,6 | sterile, Single Use 10 pcs. |
<1 mHz | ![]() |
| 891-13s | Hook Slim | 150 | 4,6 | sterile, Single Use 10 pcs. |
<1 mHz | ![]() |
| 891-14s | Hook Electrode | 150 | 4,6 | sterile, Single Use 10 pcs. |
<1 mHz | ![]() |
| 891-15s | 45° Bent Electrode | 150 | 4,6 | sterile, Single Use 10 pcs. |
<1 mHz | ![]() |
| 891-16s | 45° Electrode | 150 | 4,6 | sterile, Single Use 10 pcs. |
<1 mHz | ![]() |
| 891-17s | 45° Bendable Electrode | 150 | 4,6 | sterile, Single Use 10 pcs. |
<1 mHz | ![]() |
| 891-180ST | 90° Electrode | 150 | 3,6 | sterile, Single Use 10 pcs. |
100 kHz - 4 mHz | ![]() |
| 891-190ST | Hook Spine Electrode | 150 | 3,6 | sterile, Single Use 10 pcs. |
100 kHz - 4 mHz | ![]() |
| 891-110ST | 45° Spine Electrode | 150 | 3,6 | sterile, Single Use 10 pcs. |
100 kHz - 4 mHz | ![]() |
| 891-195ST | 150 | sterile, Single Use 10 pcs. |
100 kHz - 4 mHz | ![]() |
Handles
| Item No. | Item | Description | Image |
|---|---|---|---|
| 92889-6 | Handle with buttons | 270 mm | ![]() |
| 92889-14 | Handle with buttons | 270 mm | ![]() |
| 92888-6 | Standard Handpiece | 270 mm | ![]() |
| 92888-16 | Delicate Handpiece | 270 mm | ![]() |
Adapter
| Item No. | Item | Description | compatible Handles | Image |
|---|---|---|---|---|
| 92390 | Arthrocare | Instrument side REGER, |
92889-6, 92888-6 and 92888-16 | ![]() |
| 92387 | Ellmann | Instrument side REGER, |
92889-6, 92888-6 and 92888-16 | ![]() |
| 92392 | Mitek VUE | Instrument side REGER, |
92889-6, 92888-6 and 92888-16 | ![]() |
| 92389 | Mitek Vapr | Instrument side REGER, |
92889-6, 92888-6 and 92888-16 | ![]() |
| 92397 | Arthrex | Instrument side REGER, |
92889-14, 92888-6 and 92888-16 | ![]() |
| 92388 | BONSS | Instrument side REGER, |
92889-14, 92888-6 and 92888-16 | ![]() |
Biportal StenoBur-System

Bur System:
- 10.000 RPM forward
- 5.000 RPM oscillating
- Integrated exhaust system
- with control valve
- Foot Pedal or Hand controlled
StenoBur:
- Black covered Diamond
- for optimal contrast
- 5 different Types
- fits into the EndoScope
High Speed Drills:
-
compatible with Nouvag Handpiece
-
Single Use
-
Black covered Diamond for optimal contrast
-
up to 30.000 rpm
Hubs:
- Simple plug-and-play
- Compatible with most common
- third-party generator platforms
StenoBur System
The REGER StenoBur System has been specifically developed for the demands of biportal spine surgery. It supports the precise treatment of bony structures and enables controlled decompression while maintaining excellent visualization of the surgical field. Combining powerful drive technology, specially designed burrs, and seamless integration into the REGER platform, the system delivers an efficient workflow for modern biportal procedures.
Its high level of precision supports targeted bone removal even in demanding anatomical areas. Combined with the advantages of the biportal approach, surgeons benefit from enhanced flexibility, optimized instrument handling, and reproducible surgical steps. The result is a reliable solution for precise, minimally invasive procedures in modern spine surgery.
Benefits of the StenoBur System:
- Precise decompression and bone treatment under direct visualization
- Specifically designed for biportal spine procedures
- Seamless integration into the REGER endoscopy platform
- Enhanced flexibility, controlled workflows, and reproducible results
| Item No. | Item | Description |
|---|---|---|
| 800-000-023 | Shaver Console | For use with REGER shaver blades and burs |
| 800-000-024 | Shaver Handpiece | Special connector for REGER blades and burs |
| 800-000-025 | Foot switch | for 800-000-023 |
StenoBur
Burs – perfect for removing bone
- designed for UBE
- Various tips
- up tp 30.000 rpm
- with various Handpieces compatible
- Powerful and effective workflow
- low temperature technology
![]() |
![]() |
![]() |
![]() |
![]() |
||||
| Image | Hub | OD (mm) | Length (mm) | Diamond Bur, non protected | Diamond Bur SideGuard | RoundBur non protected | RoundBur SideGuard | Barrel Bur SideGuard |
|---|---|---|---|---|---|---|---|---|
![]() |
Nouvag (DRNO) | 4,0 | 270 | 850-136S | ||||
![]() |
REGER (DRVI) | 4,0 | 270 | 825-605-200 | 825-104-200 | 820-605-200 | 829-605-174 | 850-118 |
| 5,5 | 825-604-130 | 825-105-174 | 825-605-130 | 820-605-130 | 850-126 | |||
![]() |
Arthrex (DRAR) | 4,0 | 270 | 825-605-200 | 850-081 | 850-088 | 850-095 | 850-119 |
| 5,5 | 850-077 | 850-094 | 850-091 | 850-098 | 850-127 | |||
![]() |
Smith & Nephew (DRSN) | 4,0 | 270 | 850-075 | 850-082 | 850-089 | 850-096 | 850-120 |
| 5,5 | 850-078 | 850-085 | 850-092 | 850-099 | 850-128 | |||
![]() |
Stryker (DRST) | 4,0 | 270 | 822-104-200 | 827-605-200 | 820-104-174 | 826-105-174 | |
| 5,5 | 825-104-174 | 826-104-200 | 820-605-174 | 826-105-200 | ||||
![]() |
J&J, Nextra (DRNX) | 4,0 | 270 | 5,5 | ||||
![]() |
Conmed (DROR) | 4,0 | 270 | |||||
| 5,5 | ||||||||
Advantages of the REGER Spine System in Everyday Surgical Practice
- High precision and control – even in tight anatomical areas
- Compatible plasma and shaver technologies for maximum efficiency
- Standardized module combinations for repeatable procedures
- Workflow-optimized equipment for surgical teams and assistants
- Robust instruments & components – even with high operating frequency
For dealers & distribution partners
REGER Spinal Systems in Sales – Your Added Value
Endoscopic spine systems are among the fastest-growing segments of medical technology—with high clinical demand, specialized training requirements, and sustainable applications.
As a sales partner, you benefit from:
- MDR-compliant documents for product approval
- Technical consulting / Product training
- Product brochures & application guides
- Support with tenders and bid documents
- Attractive terms for project and key account sales
Our systems are tried and tested, modularly expandable, and strengthen your portfolio in the field of minimally invasive spinal surgery.
For clinics and healthcare professionals
Innovative technology for modern spinal surgery
REGER spine systems were developed in close consultation with users to deliver technology, safety, and efficiency in everyday surgical practice—while remaining easy to use and offering clear workflow integration.
Relevant for healthcare professionals:
- Precise instrumentation for interlaminar, transforaminal, and biportal approaches
- Plasma and shaver systems for reproducible processes
- Minimally invasive options for preserving tissue and nerves
- Training courses on safe implementation in the operating room
Your contact for all matters relating to the REGER system
If you have any questions about our products, technical details, or how to integrate them into your clinic’s processes, we’d be happy to assist you personally.
Email: info@reger-med.de